RAD makes both a 100mbps and 1000mbps version of the SFP..

http://www.rad.com/template.MEDIA_ITEM/10286_MiTOP-E3-T3.pdf?skip=true

MITOP-E3T3/+/?
Legend
+ PSN interface:
FE Fast Ethernet
GE Gigabit Ethernet
? Enclosure (Default=regular enclosure):
H Temperature-hardened enclosure
(MiTOP-E3/T3/FE units only)


On Wed, Apr 3, 2013 at 5:28 PM, Adam Vitkovsky <[email protected]>wrote:

> >(they are 100Mb/s SFPs),
> Aaah you're right these are 100Mbps SFPs -so those won't run on me3600
> right? How much is the accidian nid please? And is it reliable please?
>
> > In our scenario one end of the PWE3 is always connected to a SDH system
> that provides clocking, whilst the other runs in adaptive mode.
> I see, that's definitely one way to get a clocking into this thing -I
> guess we could bridge the other end of the PE to me3600x-cx or asr903 STM
> port to get the clocking from SDH
>
>
> adam
>
>
> _______________________________________________
> cisco-nsp mailing list  [email protected]
> https://puck.nether.net/mailman/listinfo/cisco-nsp