Hi,
On 4 April 2013 14:44, Adam Vitkovsky <[email protected]> wrote: > Hi Pshem, > What did you use as the FRR mechanism, if any, along with the BFD testing > please? Yes, we did use RSVP-TE FRR for the protection. >> it's threshold based, so once errors reach particular level switchover is >> triggered - whilst BFD has to actually lose those packets first. > Well, unless you have the expensive modules that can do the FEC you will lose > some data either way. That's correct - data loss always occurs anyway (we've noticed that L2 seems to be more prone then L3). It's about the re-convergence time - i.e. the time the packets do not arrive at the destination (either because they've been lost or because they're getting re-routed and delayed). Using WanPhy doesn't require the FEC ability (only OTU framing needs it). As one of the tests we actually took pliers to the wire to see what would happen. In our case - the traffic switched before the scissors went all the way through (logs indicated that the BER went above the thresholds before actual LOS). kind regards Pshem _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/