Hi Gustav,
Yep, as below:-
sw1.sco-edi-NEW#show mpls for 46.226.0.12 detail
Local Outgoing Prefix Bytes Label Outgoing Next Hop
Label Label or Tunnel Id Switched interface
None 306496 46.226.0.12/32 0 Tu1 point2point
MAC/Encaps=14/18, MRU=9000, Label Stack{306496}, via Te0/2
A8D0E55DD93788F07792BCDB8847 4AD40000
No output feature configured
SW1.THN-LON#show mpls for 46.226.0.10 detail
Local Outgoing Prefix Bytes Label Outgoing Next Hop
Label Label or Tunnel Id Switched interface
None 304720 46.226.0.10/32 0 Tu0 point2point
MAC/Encaps=14/18, MRU=9000, Label Stack{304720}, via Te0/2
A8D0E55DEB3D88F077938CDB8847 4A650000
--
Nick Ryce
Fluency Communications Ltd.
e. [email protected]
w. http://fluency.net.uk/
t. 0845 874 7000
From: "[email protected]<mailto:[email protected]>"
<[email protected]<mailto:[email protected]>>
Date: Friday, 7 June 2013 09:37
To: Nick Ryce <[email protected]<mailto:[email protected]>>
Cc: "[email protected]<mailto:[email protected]>"
<[email protected]<mailto:[email protected]>>, cisco-nsp
<[email protected]<mailto:[email protected]>>
Subject: Re: [c-nsp] Fwd: BGP Signalled VPLS on ME3600
Hello.
Do you have a corresponding entry in the mpls forwarding database for the next
hop address?
Bästa hälsningar / Best regards,
Gustav Uhlander
Communication & Infrastructure Engineer
Steria AB
Kungsbron 13
Box 169
SE-101 23 Stockholm
Sweden
Tel: +46 8 622 42 15
Fax: +46 8 622 42 23
Mobile: +46 70 962 71 03
[email protected]<mailto:[email protected]>
www.steria.se
From: Nick Ryce <[email protected]<mailto:[email protected]>>
To: "[email protected]<mailto:[email protected]>"
<[email protected]<mailto:[email protected]>>
Date: 2013-06-06 20:11
Subject: [c-nsp] Fwd: BGP Signalled VPLS on ME3600
Sent by: "cisco-nsp"
<[email protected]<mailto:[email protected]>>
________________________________
Hi,
Im having a strange issue with a BGP signalled VPLS on my ME3600. I'm running
15.3.2(s).
The VFI comes up but the virtual circuit stays down with the following error:-
SW1.THN-LON#show mpls L2transport vc 501 detail
Local interface: VFI FLVPLS001 vfi up
Interworking type is Ethernet
Destination address: 46.226.0.10, VC ID: 501, VC status: down
Last error: MPLS dataplane reported a fault to the nexthop
Output interface: none, imposed label stack {}
Preferred path: not configured
Default path: no route
No adjacency
Create time: 00:19:42, last status change time: 00:19:42
Last label FSM state change time: 00:19:42
Signaling protocol: BGP
Status TLV support (local/remote) : Not Applicable
LDP route watch : Not Applicable
Label/status state machine : activating, LruRruD
Last local dataplane status rcvd: DOWN(pw-tx-fault)
Last BFD dataplane status rcvd: Not Applicable
Last BFD peer monitor status rcvd: Not Applicable
Last local AC circuit status rcvd: No fault
Last local AC circuit status sent: DOWN(pw-rx-fault)
Last local PW i/f circ status rcvd: No fault
Last local LDP TLV status sent: Not Applicable
Last remote LDP TLV status rcvd: Not Applicable
Last remote LDP ADJ status rcvd: Not Applicable
MPLS VC labels: local 27, remote 16
Group ID: local 0, remote 0
MTU: local 1500, remote 1500
Control Word: Off
Dataplane:
SSM segment/switch IDs: 0/10075 (used), PWID: 12
VC statistics:
transit packet totals: receive 0, send 0
transit byte totals: receive 0, send 0
transit packet drops: receive 0, seq error 0, send 0
The next hop is available and routable so not quite sure what the issue is.
Any help greatly appreciated.
Nick
_______________________________________________
cisco-nsp mailing list
[email protected]<mailto:[email protected]>
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/
_______________________________________________
cisco-nsp mailing list [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/