On Nov 29, 2013, at 6:09 PM, Nikolay Shopik <[email protected]> wrote:

> Even when you draw graph in 5 min interval?

Yes.  Your graphs will be way off unless you bring the active timer down to 
60s, irrespective of graph resolution.

You should also consider graphing with 1-minute intervals, it's more 
operationally useful.

> As lowering values means more flows exported per min so more load.

NDE is going to consume a very low CPU percentage, normally single-digit; if 
you're so close to the edge that NDE load matters, you have bigger problems.

;>

-----------------------------------------------------------------------
Roland Dobbins <[email protected]> // <http://www.arbornetworks.com>

          Luck is the residue of opportunity and design.

                       -- John Milton


_______________________________________________
cisco-nsp mailing list  [email protected]
https://puck.nether.net/mailman/listinfo/cisco-nsp
archive at http://puck.nether.net/pipermail/cisco-nsp/