http://www.fragmentationneeded.net/2010/10/you-can-connect-switch-to-nexus-fabric.html
Have a quick read of this - I haven't used it, but it suggests that running Flexlink on the 2960/3560 uplinks would work JBYCDMYS :-) On Wed, Dec 11, 2013 at 11:51 PM, Douglas C. Stephens <[email protected]>wrote: > Joeseph, > > The other responders are correct that the Nexus 2000 series fabric > extenders are > not switches. Nevertheless, I was forced to deal with a situation > recently where > a customer had installed a managed switch downstream of one of my 2248 > fabric > extenders, so even though it doesn't involve VPC, maybe it helps you or > somebody. > > I had the ports on this 2248 fabric extender all configured with > "spanning-tree port > type edge", since that is what I expected all the downstream equipment to > be. > One day several links began flapping all the time because STP BPDUs would > be > generated by the customer's switch, cause the port on the 2248 to > err-disable, > the 5 minutes later err-recover would kick in and re-enble the port -- > rinse and > repeat. This generated a lot of log noise that looked like this (note the > lines > in the middle referencing BPDUGuard): > > %ETHPORT-5-SPEED: Interface Ethernet103/1/13, operational speed changed to > 1 Gbps > %ETHPORT-5-IF_DUPLEX: Interface Ethernet103/1/13, operational duplex mode > changed to Full > %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet103/1/13, operational > Receive Flow Control state changed to off > %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet103/1/13, operational > Transmit Flow Control state changed to on > %ETHPORT-5-IF_UP: Interface Ethernet103/1/13 is up in mode access > %ETHPORT-5-IF_DOWN_NONE: Interface Ethernet103/1/13 is down (None) > %ETHPORT-5-IF_DOWN_ERROR_DISABLED: Interface Ethernet103/1/13 is down > (Error disabled. Reason:BPDUGuard) > %ETHPORT-5-IF_ERRDIS_RECOVERY: Interface Ethernet103/1/13 is being > recovered from error disabled state (Last Reason:BPDUGuard) > %ETHPORT-5-SPEED: Interface Ethernet103/1/13, operational speed changed to > 1 Gbps > %ETHPORT-5-IF_DUPLEX: Interface Ethernet103/1/13, operational duplex mode > changed to Full > %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet103/1/13, operational > Receive Flow Control state changed to off > %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet103/1/13, operational > Transmit Flow Control state changed to on > %ETHPORT-5-IF_UP: Interface Ethernet103/1/13 is up in mode access > > A solution that worked for me for this situation I found referenced at > Cisco here > described as enabling BPDUfilter: > > > http://www.cisco.com/en/US/docs/switches/datacenter/nexus5000/sw/troubleshooting/guide/n5K_ts_l2.html#wp1026440 > > I implemented this on the affected 2248 ports like this: > > config t > interface Ethernet103/1/13 > no spanning-tree port type edge > spanning-tree bpdufilter enable > exit > > Once changed, as soon as err-recovery re-enabled the ports, they stayed > enabled. > Once I became aware that the customer had used a managed switch with STP > running, > and then had to implement this solution, I "educated" the customer to make > sure > nothing was connected to that switch except physical servers. > > > At 06:56 PM 12/10/2013, Joseph Hardeman wrote: > >Hi Everyone, > > > >I knew I should have come here first but I went with the word of a CCXX > >something or another (Director of IT) from a vendor and a couple links he > >sent me. After I explained the setup I was putting together and how > >everything needed to work together, he told me that the Nexus 2232PP > Switch > >could do what I wanted and needed. > > > >I have a pair of 2232PP FEX switches that we just got to extend our 5000 > >series switches from one cage to another (I have never worked with the FEX > >Switches before, so I should have done better homework). We were going to > >use the pair of FEX switches to provide redundant links to additional > >switches from which I was going to connect to customer switches or > >firewalls. Which going through the initial config today on setting up the > >VPC port on say Eth100/1/1 for my first test switch, I got an error saying > >that the VPC could not be added that there was one already applied. > > > >I reached out to the TAC Contact I have that has helped me out this week, > >and he told me that the FEX Switches were never meant to connect to other > >switches and the BPDUGuard would shut down the ports to the switch shortly > >after the ports come up. And it was not just this model but any FEX > Switch. > > > >So my question to you guys is, (drum roll please): > > > >Does anyone have a Nexus 2000 FEX Switch Pair doing VPC Port Channel to > >another switch instead of a host/server? And if you do how did you make > it > >work. I am considering returning these switches as I can't use them right > >now and I really need a usable pair of switches for the 10G+ cage to cage > >connectivity and then 1 or 10G to either my switches or customer switches. > > Which my switches then step it down to either 100M or 10M if needed. > > > >Is there a FEX switch that will do this? (imagine the full mesh setup) > > > >routers -> 5000Switch -> FEX Switch -> 2960G or 3560G (for example) switch > >-> Possible other switching/firewall gear -> end system > > > >Can you recommend any other switch that can do what I want, or should I > >just get another pair of 5000 series switches? > > > >Thanks, > > > >Any thoughts or suggestions would be helpful. > > > >Joe > >_______________________________________________ > >cisco-nsp mailing list [email protected] > >https://puck.nether.net/mailman/listinfo/cisco-nsp > >archive at http://puck.nether.net/pipermail/cisco-nsp/ > > -- > Douglas C. Stephens | Network/DNS/Unix/Windows Admin > System Support Specialist | Email Postmaster > Information Technology | Phone: (515) 294-6102 > Ames Laboratory, US DOE | Email: [email protected] > > _______________________________________________ > cisco-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/cisco-nsp > archive at http://puck.nether.net/pipermail/cisco-nsp/ > _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/