Hi Ali,

First of all I'd try to get a L2 transparent circuit from the provider not just 
a single VLAN -might be available at the same price. 
If that's not an option than I'd try to double tag the frames on the uplink to 
the provider as follows:  
(Please check whether there's enough MTU on the uplink)
 
interface GigabitEthernet0/13
 mtu 1512
 service instance 25 ethernet
  descript transport customer1
  encapsulation dot1q 100 second-dot1q 10  
  rewrite ingress tag pop 2 symmetric  
  bridge-domain 25
 !
 service instance 20 ethernet
  descript management
  encapsulation dot1q 100 second-dot1q 20  
  rewrite ingress tag pop 2 symmetric  
  bridge-domain 20

interface vlan 20
 descript switch management interface
 vrf for mgmt
 ip add 10.0.0.1 255.255.255.252



Interface GigabitEthernet0/19 
 port-type nni 
 switchport trunk allowed vlan none
 switchport mode trunk 
 mtu 1504 
 service instance 26 ethernet
  descript to customer1 
  encapsulation dot1q 200,433,472 
  bridge-domain 25


adam