On May 21, 2014, at 2:52 PM, Eric Van Tol <[email protected]> wrote:
>> From: cisco-nsp [mailto:[email protected]] On Behalf Of >> Scott Granados >> Sent: Wednesday, May 21, 2014 2:32 PM >> >> Hi, >> First, thanks for all the great input on analyzers and their strong and >> weak points. It looks like from the comments I'm going to give nfsen a >> shot. >> My followup question concerns selection of interfaces and the >> direction to monitor. While googling I find that almost all examples I >> find are sampling in the input direction only. Also most of the examples >> out there seem to be quite simple and involve one interface or a few. > > I think this really all depends on what you want to see. If you want a full > profile of where your traffic is headed, I believe it's best to run it as > close to the "edge" as possible - both at customer/user-facing ports and at > AS boundary ports. In addition, anything in between that you might want more > granular data from, such as service networks hanging off your core. I recall seeing cautions from long ago about using both ingress and egress on an interface. On my old NPE-G2, it seemed to work. I have not re-enabled it on our ASR1K yet as I’ve not had the time to research this, and I also want to complete the move to nfsen from the old flow-tools package. I understand the old recommendation - ingress on all interfaces should catch all traffic in both directions. But what I’m dealing with is a single box with two transit interfaces and a ton of subscriber interfaces (subinterface per customer basically). It seems unwise (and complicated) to add an ingress flow statement on every subinterface. If I could just add an “ingress” and “egress” statement to each of my two transit connections, that seems more ideal. Is this something I should *not* do on modern hardware? If so, what other options are there short of adding an ingress monitor on hundreds of subinterfaces? Thanks, Charles > I could be wrong, but I think the type of metering you can do > (ingress/egress) depends on the Netflow version you plan on running. I > believe version 5 can only do ingress metering. However, if you have ingress > metering configured on all edge-facing ports and all core-facing ports, you > can expect to get everything you need, because the return traffic from an > edge port will be seen as an ingress flow on a core port. I'm not sure of > the benefits you would get by using v9 or IPFIX and doing both ingress/egress > metering, as it would seem to me that you're just duplicating flow data at > that point. I think it really all depends on your traffic flow patterns. > That said, if your devices support it, v9 or IPFIX would be the way to go. > > -evt > > > > _______________________________________________ > cisco-nsp mailing list [email protected] > https://puck.nether.net/mailman/listinfo/cisco-nsp > archive at http://puck.nether.net/pipermail/cisco-nsp/ _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/