On 8/18/14, 2:51 PM, [email protected] wrote:

>Do you know any devices to provide galvanic isolation for twisted pair
>Ethernet?


At Interop a few years back, Extreme switches in the infrastructure were being blown up and we turned to APC isolation equipment. They had a nice little 1U unit that seemed to do the trick.

http://www.apc.com/products/family/index.cfm?id=145

Obviously it would be better to figure out the problem---probably ground loop-related---but this might buy you some time while you figure out what the problem is and, more importantly, how to solve it (which can be very difficult or even impossible in some buildings).

jms


--
Joel M Snyder, 1404 East Lind Road, Tucson, AZ, 85719
Senior Partner, Opus One       Phone: +1 520 324 0494