Yes, I have checked config of working Trunk and no difference. Rgds Harry Harry Hambi BEng(Hons) MIET Rsgb
-----Original Message----- From: Nick Hilliard [mailto:[email protected]] Sent: 22 October 2014 15:39 To: Harry Hambi - Atos; '[email protected]' Subject: Re: [c-nsp] LACP Trunk between Cisco VSS and Brocade MLX. On 22/10/2014 15:31, Harry Hambi - Atos wrote: > Has anyone seen this error ?. yes, it's normally caused by misconfiguration. Both brocade netiron and cisco IOS have mature 802.3ad/LACP implementations which interoperate nicely. Nick _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/