Hi All, Excellent thanks for this, I'm surprised we have never seen it before but it certainly seems like a perfect match for our symptoms. That has saved me a lot of additional time trying to work this out. I guess those links must have been added at the same time 6 months ago :)
So, many thanks everyone! Cheers, > Robert Williams Custodian Data Centre Email: [email protected] http://www.CustodianDC.com -----Original Message----- > From: cisco-nsp [mailto:[email protected]] On Behalf Of > Saku Ytti > Sent: Thursday, March 17, 2016 12:20 PM > To: Robert Williams <[email protected]> > Cc: [email protected] > Subject: Re: [c-nsp] Strange X2 Temperature Flaps > > > This is buggy microcontroller from gigalight where after 2**31 1/100th > of a second you start to write clock in temperature sensor memory-area. > > > Fun times when you have tons of these, and in maintenance window boot > lot of devices, then after 2**31 has passed, they all go down at the > same time. Reminder that no amount of redundancy really guarantees you > anything. > > For what it is worth, gigalight handled this issue extremely well for > us, even though we didn't do any business with them. But the broker who > sold them to us, 'network wide' was my worst experience ever. > > -- > ++ytti _______________________________________________ cisco-nsp mailing list [email protected] https://puck.nether.net/mailman/listinfo/cisco-nsp archive at http://puck.nether.net/pipermail/cisco-nsp/