On Fri, 5 May 2017, Drew Weaver wrote:

We had a PSU failure in a 6513 and we want to replace the failed one (which is a: WS-CAC-4000W) but currently what we have in stock is a whole lot of these: WS-CAC-6000W

I know that it should be possible to run a switch with two different sized power supplies (because it would make upgrading possible) but are there any known caveats to this?

Scratch that last message. Helps if I take time to read :) I misread that as you had a failed 6000 watt PSU and needed to replace it with a 4000 watt unit.

Other than the switch complaining about mismatched power supplies, you should be OK. You're running 208 volt power, correct?