Someone wrote to say that you use a null HSSI which is absolutely correct.
I'd like to add that the timing setup is tricky - if you just set clock rate
you'll see CDP making it from the DCE to the DTE device but you won't be able
to establish two way communications. There is also a 'hssi dce' or something
like that which must be set.


   Not all Cisco HSSI ports are the same. I've had an easy time getting this to
work with a PA-H or PA-2H and a not so easy time getting it to go with a
CX-HIP.


rtc wrote:

>  A HSSI high density serial port is 50 pins and the size of a normal PC
> serial connector.
> We need a cale that goes  [50pinHSSI high density serial port]--- [50pinHSSI
> high density serial port]
>
> Its the only we can tie our 7513 to our other 3 routers because we cant
> afford more Ethernet Boards.
>
> ___________________________________
> UPDATED Posting Guidelines: http://www.groupstudy.com/list/guide.html
> FAQ, list archives, and subscription info: http://www.groupstudy.com
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

___________________________________