Explanation   This message indicates an underflow in the port ASIC transmit
buffer. The first [dec] is the module number. The second [dec] is the ASIC
port number.

Action If the error is limited to a single module, replace the module. If
the error occurs several times, contact your technical support representative

Hope this helps !!!!! :)

-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
Sent: Thursday, June 26, 2003 9:07 PM
To: [EMAIL PROTECTED]
Subject: Issue with 6509 [7:71468]


Having a problem with 12 ports on one of our 6509's.. They are unable to
pass traffic, and I get the following errors on the console.

2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow 
Error - Port #2:
2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow 
Error - Port #3:
2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow 
Error - Port #4:
2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow 
Error - Port #5:
2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow 
Error - Port #6:
2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow 
Error - Port #7:
2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow 
Error - Port #8:
2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow 
Error - Port #9:
2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow 
Error - Port #10:
2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow 
Error - Port #11:
2003 Jun 26 10:55:57 %SYS-3-SYS_LCPERR3:Module 6: Coil Pb Tx Underflow 
Error - Port #12:



Does anyone know what this means?



Thanks, 

Mario Puras 
SoluNet Technical Support
Mailto: [EMAIL PROTECTED]
Direct: (321) 309-1410  
888.449.5766 (USA) / 888.SOLUNET (Canada)
NOTICE - This message contains privileged and confidential 
information intended only for the use of the addressee 
named above. Any review, retransmission, dissemination, 
copying, disclosure or other use of, or taking of any 
action in reliance upon, this information by person or 
entities other than the intended recipient is prohibited. 
If you have received this message in error, please notify 
the sender by return email and delete this message. 
This message should not be copied or used for any purpose 
other than intended, nor should it be disclosed to any 
other person. Any views expressed in this message are those 
of the individual sender, except where the sender specifically
 states them to be the view of Investec Group, its 
subsidiaries or associates. The Investec Group is not 
liable for the security of information sent by e-mail at 
your request, nor for the proper and complete transmission 
of the information contained in the communication nor for 
any delay in its receipt. Please note that the recipient 
must scan this e-mail and any attached files for viruses 
and the like. The Investec Group accepts no liability of 
whatever nature for any loss, liability, damage or expense 
resulting directly or indirectly from the access of any files 
which are attached to this message.




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=71685&t=71468
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to