Can
you just use a static route and see if that has any affect?
Dave
HI,
I have strange problem with one of my customer
router. The users in the branch will not be able to connect to the HO for
sometimes and when I checked the serial it shows (serial is up and line
protocol is up) but when I gave(show ip route) I could not see the branch n/w
subnet route, I could not be able to ping the ethernet ip address of the
branch from HO. When I gave shutdown and no shutdown at the HO serial, I can
see the branch subnet and the users can access the server. Iam using RIP. I
tried changing the keepalive to 5sec but no use.
Is it h/w problem, but Iam getting this very
rarely(twice, sometime in a week).
thanks
imran
|