I have a PRI card on my cisco 7206 and have the following configuration

controller t1 3/0
clock source internal
channel-group 23 timeslots 1-24


interface serial3/0:23
ip address 196.168.1.1 255.255.255.0

this is suppose to be a point to point circuit.

Can anyone shed some light as to why the configuration above is as is and 
since it's suppose to be a point to point circuit, why is it using 
controller ... and serial3/0:23.  the connection is up and running but i'm 
having a hard time trying to understand this thing.

thanks.