These commands do work on this version of PIX, although Cisco says their
recommended method is to now use access lists.  Did you "clear xlate"?  Any
time you add, change, or delete statics and conduits, you must clear the
translations.  Of course, you could also reboot the box.   ;-}

Rik


"NP-BASS LEON" <[EMAIL PROTECTED]> wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> I was trying to add a Static and Conduit statement to a PIX ver 5.3(1) and
> could not get it to add.
> It would add to the PIX, but it was going to the end of the Static list or
> the end of the conduit list, and performed as if it was an extended
> access-list, The PIX box was not recognizing the entry at all, even after
I
> syncronized the two  by writing to mem and writing to Standby.
> Any helpful hints would be appreciated.
>
>
>
> Thanks in advance.
>
> _________________________________
> FAQ, list archives, and subscription info:
http://www.groupstudy.com/list/cisco.html
> Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]
>


_________________________________
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to