Hi Group Just to share with you, a few days ago on the 27th I had asked ofr help regarding the AS400. Now it seems like presently the problem is solved. The AS400 team increased the MTU on the AS400 box to 4096 and it seems to work okay. This is very strange because the mtu defined on our router is 1500. I can texpalin the theory behind this but for now it jsut worked. Earlier we used to get a DR watson error at the branch servers. the dr watson error was something like this. If anybody can interpret this 28/03/2001 19:54:03 DrWatson Information None 4097 N/A U9010117 The application, ..\..\bin\rt.exe, generated an application error The error occurred on 3/28/2001 @ 19:53:57.768 The exception generated was c0000017 at address 77f64aef (RtlAllocateHeap) 28/03/2001 18:37:42 SNA Base Service Information None 626 NT AUTHORITY\SYSTEM U9010117 Service started EXPLANATION The service shown in the message header started successfully. ACTION No action is necessary. 28/03/2001 18:37:21 OliMon None None 100 N/A U9010117 Olivetti PR 50 Port Monitor initialization completed successfully 28/03/2001 18:31:31 DrWatson Information None 4097 N/A U9010117 The application, ..\..\bin\rt.exe, generated an application error The error occurred on 3/28/2001 @ 18:31:26.186 The exception generated was c0000017 at address 77f64aef (RtlAllocateHeap) 28/03/2001 18:27:46 SNA Base Service Information None 626 NT AUTHORITY\SYSTEM U9010117 Service started But after the MTU size was changes the Dr Watson Error has disappeared. Best Regards, Gayathri _________________________________ FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]