What causes a CRC error on the token ring port and what is a soft error....
JOHANNESBURG#sho int to 0/0
TokenRing0/0 is up, line protocol is up
Hardware is IBM2692, address is 0007.7829.1b43 (bia 0007.7829.1b43)
Internet address is x.x.x.x
MTU 8136 bytes, BW 16000 Kbit, DLY 630 usec,
reliability 255/255, txload 3/255, rxload 1/255
Encapsulation SNAP, loopback not set
Keepalive set (10 sec)
ARP type: SNAP, ARP Timeout 04:00:00
Ring speed: 16 Mbps
Duplex: half
Mode: Classic token ring station
Source bridging enabled, srn 1025 bn 1 trn 1997 (ring group)
spanning explorer enabled
Group Address: 0x00000000, Functional Address: 0x0880001A
Ethernet Transit OUI: 0x000000
Last Ring Status 00:00:08 (0x2000)
Last input 00:00:00, output 00:00:00, output hang never
Last clearing of "show interface" counters 00:04:36
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue :0/40 (size/max)
5 minute input rate 63000 bits/sec, 53 packets/sec
5 minute output rate 193000 bits/sec, 49 packets/sec
15161 packets input, 2224430 bytes, 0 no buffer
Received 1304 broadcasts, 0 runts, 0 giants, 0 throttles
60 input errors, 60 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
15150 packets output, 8156480 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets
0 output buffer failures, 0 output buffers swapped out
0 transitions
Thanks
Andrew
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=3596&t=3596
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html