Had nothing better to do than sell my easy to configure & predictably slow
2511 for a 2621 with an NM-16 async module. I am @ a loss as to logic
involved with the async line numbering. With the 2500 Access-Server, line 1
is 2001 (2000 being Telnet protocol). My 2621 has the NM-16 in slot 1 (as
seen in the below output):
Firewall#sh diag
Slot 1:
Async port adapter, 16 ports
The given formula is this: interface # = (16 x slot #) + unit # +1
(16x slot # 1) + 1 (physical connection 1) + 1= gives me 18 The router
starts the count @ 33 as the first useable line #. So- my range of 16
useable
lines is 33 thru 48. My question is:
What gives ???
What's the logic here ???
Thanks !!!
Phil