make sure you don thave the command 'no keepalive' in the interface which is
affected

"Hire, Ejay"  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Based on what I'm seeing, I think there is a problem with the data
returning
> from the telco cloud.  Can you loopback the CSU/DSU and see if your RX
> counter increments? If yes, Then switch the cable from the csu/dsu to the
> smartjack.  Un=loop and test.  If it still doesn't work, Loopback the
> smartjack and see if you can see the loopback remotely.  If you can't,
call
> the Loop Provider, there is a problem with the loop.
>
> -ejh
>
> -----Original Message-----
> From: Andrew Larkins [mailto:[EMAIL PROTECTED]]
> Sent: Wednesday, July 18, 2001 6:06 AM
> To: [EMAIL PROTECTED]
> Subject: WAN link funnies - UP UP but no comms- on same subnet!!!
> [7:12774]
>
>
> HI all,
>
> Strange problem here.
>
> The serial interface are UP UP on both sides, but we are not able to ping
> each other  - even though directly connected. A "debug ip ICMP" on the
> remote site shows the ping coming through and replying, but the reply
never
> gets back.
> Also the remote site saw my router using CDP, but I do not see him.
>
> Any ideas??
>
> I believe this is Telco related, but the line shows clean from the
interface
> stats
>
> Andrew