Joe,
Responding a bit late, but I had exactly the same problem today.
Eventually found that I had to use the specific cable, luckily I found one.
The difference between the specific cable and a standard rolled cable with
two terminal connectors, seems to be that pins 1and 6 are looped on the OEM
cable.
Pin 1 is not even connected in the standard cisco connectors.
I reckon if you can get pin 1 and 6 looped somehow on the switch the normal
cable may work. Otherwise get the real cable.
The following link has the right cable at Figure A6:
http://www.cisco.com/univercd/cc/td/doc/product/lan/28201900/1928v5x/icg5x/c
sspec.htm#41267
Watch the wrap.
Gaz
wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> Hello,
> I want to thank all who responded to my problem of accessing through the
> console port. the problem was a background program that tied up the COM1
> port.
> Now when i access my 1924 switch , it responds with the letters "ATQOHO"
and
> "ATQOZO" and just sits there. I am wondering if the flash is corupted and
i
> need to reload the operating system or if i have a bigger problem. I have
> looked at the cisco site and nothing came up regaurding the problem.
> thank you for your time,
> Joe gearhart, CCNP
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=13106&t=11261
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html