I'm racking my brain trying to think of how one could accomplish this.
on the frame ( layer 2 ) level, a DLCI is an end point identifier of a PVC.
you need a unique DLCI for each PVC at the hub. one DLCI at the hub for each
PVC to a specific hub.
I'm curious where you heard that a signal DLCI was all that was necessary.
Chuck
-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of
vr4drvr .
Sent: Wednesday, August 01, 2001 7:41 AM
To: [EMAIL PROTECTED]
Subject: OT: Frame Relay Q [7:14495]
Has anyone ever configured a hub and spoke FR topology (2 seperate subnets)
with a single DLCI at each point? If so, please explain how. I always
understood that the hub had to have 2 DLCI's for this to work.
TIA.
Adrian Smith
Network Engineer
AIM: vr4drvr
_________________________________________________________________
Get your FREE download of MSN Explorer at http://explorer.msn.com/intl.asp
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=14587&t=14495
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]