No one has mentioned it yet but make sure that the little pin beside the
6509 console port is in the "in" position. This position allows the rollover
cable to work. This position will also allow the 2620 cable to connect
directly to the 6509. If this doesn't work it is likely a config issue on
the 2620.
Another issue issue to ensure that all lines are clear before trying a
reverse telnet. Use a "where" command to ensure that you do not have an open
connection to the port you are trying to reverse telnet to. If you have an
open connection you can clear the line with "clear line x" or resume the
connection by typing the line number.
--Rich
-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of
cisco skin
Sent: Wednesday, August 01, 2001 1:57 PM
To: [EMAIL PROTECTED]
Subject: Terminal server and Cat6509 [7:14535]
I'm having a piss os a time with a 2620 with a 16port Asych module/octal
cables attached.... plugged into my console port on a 6509. Cant't get the
bastard to work... tried with just the console, than even attached sl0 with
an IP address... still nada. I'm sure I have the right line by doing a "sh
line".... Any help would be much appreciated. I've even used this link in
case someone tries to point it out:
:http://www.cisco.com/warp/customer/793/access_dial/comm_server.html
Thanks
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=14591&t=14535
--------------------------------------------------