Thank you very much. Actually we just found this out today from someone
else. I think they said a Sup III, but regardless, we put in our Sup III and
it works..

Also didn't realize the Sup III required a straight through for the
console...

Thanks for the reply,
Tim Booth
----- Original Message -----
From: "Ed Moss" 
To: 
Sent: Tuesday, October 02, 2001 4:58 PM
Subject: Re: Token Ring Module Problem for Catalyst 5000 [7:21610]


> The WS-X5030 Token Ring Module requires a Supervisor II to function.
> A SUP I provides similar results to what you state.... the Cat keeps
saying
> the module is resetting or faulty.  If you do a sho modules, or a show
> version,  I believe the software/firmware versions will report 0.0.
>
> Ed




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=21759&t=21610
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to