Thanks Tim Hickman for his correct response.  The 4006 has 3 power
supplies, needs two to run and I had the third turned off hence the
faulty status.

  time for eine bier!!!

  Dave

MADMAN wrote:
> 
> Just working with a customer whose Cat4K had "lost" all it's line
> cards.  Anyway got it back up and working but the customer noticed the
> the status of the sup card was faulty, running 6.1.2 catOS.  I logged
> into my cat4k in the lab running 6.1.3 and noticed the same thing.  Must
> be cosmetic, anyone else see/seen this????
> 
> Mod Slot Ports Module-Type               Model               Sub Status
> --- ---- ----- ------------------------- ------------------- ---
> --------
> 1   1    2     1000BaseX Supervisor      WS-X4013            no  faulty
> 2   2    34    Router Switch Card        WS-X4232-L3         no  ok
> 3   3    48    Inline Power Module       WS-X4148-RJ45V      no  ok
> 4   4    1     Voice Gateway             WS-X4604-GWY        no  ok
> 
> 
> --
> David Madland
> Sr. Network Engineer
> CCIE# 2016
> Qwest Communications Int. Inc.
> [EMAIL PROTECTED]
> 612-664-3367
> 
> "Emotion should reflect reason not guide it"
-- 
David Madland
Sr. Network Engineer
CCIE# 2016
Qwest Communications Int. Inc.
[EMAIL PROTECTED]
612-664-3367

"Emotion should reflect reason not guide it"




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=22080&t=22067
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to