I haven't seen that one but I recently had a customer that could not
get this custom server to connect on a 6509 pwr card.  I then tried
disabling the power, 
"set port inlinepower mod/port off" and that fixed it.  I assume that
there may be a similiar comand on the 35xx that disables power.

  Dave

Richard Dennard wrote:
> 
> Hello everyone,
> 
> Problems with 3524-PWR-XL?  Has anyone had any problems with this switch
> injecting power on ethernet cards causing them to burn out?  We have had
> to replace over 100 cards this month and cannot determine resolution.
> Cisco says it supplies power to only devices that require it or can
> accept it, but I can't find anything else that could do this. I know
> this is not the venue to ask job related questions but have run out of
> resources.  (ex. CCO, TAC, etc.) Any thoughts on this would be
> appreciated...  Thanks for your help.
> 
> Richard Dennard
> Systems Engineer CCNA CCDA
> Central Data, Inc.
-- 
David Madland
Sr. Network Engineer
CCIE# 2016
Qwest Communications Int. Inc.
[EMAIL PROTECTED]
612-664-3367

"Emotion should reflect reason not guide it"




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=23415&t=23415
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html