yes. and this is a good command to know. when you telnet someplace, there is a time during which the source waits for the SYN to come back from your target. But suppose you mis-type a command? You wait and wait while the domain-lookup occurs, until the default syn wait time expires.
the ip tcp synwait-time X shortens that wait to something tolerable. no ip domain lookup is another good one, and accomplishes something similar. but in many environments there is reason to have domain-lookup enabled. HTH Chuck -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of Bill Reilly Sent: Sunday, October 28, 2001 5:56 PM To: [EMAIL PROTECTED] Subject: IOS Command Question? [7:24448] I was wondering if some could shead some light on this command. ip tcp syn-wait 5 Thanks in advance.... Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=24465&t=24448 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]