Yes it is possible. You must have Sup 2 and MSFC2 to do this. Is called
"Single Router Mode". If only Sup 1 is available, you can configure "high
availability" feature and use "alternate" command in the primary router
configuration.

AG


-----Original Message-----
From: James L Williams [mailto:[EMAIL PROTECTED]]
Sent: Monday, November 19, 2001 2:26 PM
To: [EMAIL PROTECTED]
Subject: Mfsc [7:26752]


Is their a way to have redundant MSFC's on the same switch sync their
config's the same way redundant supervisor engines sync their config's?

James L. Williams, CCNP, CCDP, MCSE
Network Engineer
614-217-2143 Desk
614-419-9697 Cell




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=26753&t=26752
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to