I have had lots of FCS and collision errors on ports where one end is full
duplex and the other half. [this is on general with switches, i dont think
its 6509 specific]

check his PC's nic settings re: FDx and speed, autonegotiation and compare
that to the 6509 port's.

I'd suspect that his PC is probably half duplexing and the switch is
full.
 
BTW you probably want to just nail the port (and NIC) to a given speed and
duplex.

-j.

--
John W Reames / Director, Academic Computing, Morgan State University, MD
[EMAIL PROTECTED] / http://jewel.morgan.edu/~reames / Fax: 410-319-3604
Calloway Hall Rm 326 / Voice: 443-885-3512 / Voicemail: 443-885-4502