Try this:

service timestamps debug datetime localtime show-timezone
service timestamps log datetime localtime show-timezone
!
clock timezone EST -5
clock summer-time EDT recurring



Clayton Dukes
Cisco Info Center SE
CCNA, CCDA, CCDP, CCNP, NCC
(h) 904-292-1881
(c) 904-477-7825
------------------------------------------
Free Cisco Training at http://www.gdd.net



----- Original Message -----
From: "Alex Lee" 
To: 
Sent: Friday, May 24, 2002 10:53 AM
Subject: Re: SYSLOG time stamp problem [7:44949]


> My take is that the time stamp is correct but it is using UTC time which
is
> 4 hour ahead of U.S. East Coast's Day Light Saving Time.
>
> ""Jeffrey Reed""  wrote in message
> [EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> > I set up a syslog server and have a problem with the time stamp in a sys
> log
> > message. When a message is sent to my syslog server (using solar winds
> > syslog monitor) the date/time field is correct, but the time stamp with
> the
> > message itself is not, its 4 hours ahead. I show calendar and clock on
the
> > 6500 MSFC and they are both set correctly. I have the system set up for
> EST
> > and daylight savings, so I think the syslog facility is not factoring in
> > those settings.