Running into an issue that I can duplicate in the lab and was
wondering if anyone had noticed this behavior.  6500 with dual sups/MSFC
and a FLEXWAN, I am testing with a 4 ports serial PA but seen problem
with PA-A3-T3 also.  When converting to single router mode, (SRM) I
write erase the MSFC on the sup in mod2.  Then configure the MSFC in mod
1 for SRM.  Go back to sup in mod2 and type the three lines for SRM on
it and it synchs up just fine.  At this point VLANs and serial
interfaces are operational from active MSFC in mod1.  Test failover by
doing a "switch sup", sup/MSFC in mod2 take over.  All the VLANs work
fine but the serials are in the administratively shutdown mode.  Do a no
shut on serials and they work and they continue to work subsequently.

  Got TAC looking at it but their not sure at this point.

  Thanks

  Dave
-- 
David Madland
Sr. Network Engineer
CCIE# 2016
Qwest Communications Int. Inc.
[EMAIL PROTECTED]
612-664-3367

"Emotion should reflect reason not guide it"




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=46302&t=46302
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to