Speaking of stateful PIX's, if I make a change on 1 PIX, and it has failover
on, will it automatically make a change on the other PIX?


""Gaz""  wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
> In article , [EMAIL PROTECTED]
> says...
> > Hi,
> >
> > In a Stataful configuration, and two PIX are interconnected via a
> > dedicated Failover Fastethernet, in case of the Active unit's Internal
> > interface fails, is there any method to shift traffic to the Standby
> > unit's Internal interface to maintain connectivity, thanks.
> >
> > Leo
> > Best Regards.
> Not sure what you mean there. That's what failover does unless I'm
> misunderstanding your question.
>
> You configure the main IP address for the interface and you configure a
> failover address. If the Pix's decide that the active one has a problem
> (power,interface down etc) the secondary pix takes over the main IP
> address.
> If the primary is still contactable it will have the failover IP address
> on its inside interface.
>
> That's why it's safe to telnet to the main IP address and you know that
> you're on the active Pix, but by console you need to do a show fail to
> make sure the device you're on is primary active or secondary active
> before you make changes.
>
> Regards,
>
> Gaz




Message Posted at: