Might want to review this: http://www.cisco.com/warp/public/473/46.html
Power management was causing a bunch of issues at one of my customer's sites. Might want to disable it and see if it helps any. Frank Jimenez, CCIE #5738 [EMAIL PROTECTED] -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] On Behalf Of Dain Deutschman Sent: Wednesday, August 14, 2002 10:26 PM To: [EMAIL PROTECTED] Subject: Re: Catalyst 2950 CRC Errors [7:51419] Also...I have tested the wiring(basic tester...no NEXT/FEXT or other factors...but lengths of cable are under 50ft) and replaced patch cables...still no luck. Dain. ""Dain Deutschman"" wrote in message [EMAIL PROTECTED]">news:[EMAIL PROTECTED]... > Hello Everyone, > > I have a Cat2950 in a small office throwing up thousands of CRCs, > input errors and several runts on the port connected to the server. > Clients are getting disconnected and database on server is constantly > having to be repaired. The errors always follow the server no matter > which port I move it > to. Have replaced NIC in server and a few key Wkst. Have also updated > the NIC drivers. ( Win2000 w/3C905C-TX-M Nics ). I have forced speed > and duplex > settings and disabled spanning-tree. I'm suspecting dirty power...but > it is > connected to a UPS ( that only has limited EMI/RFI Filtering ). I > connect a > 3Com unmanaged 8 port switch to the key clients and the server...no > more problems. Any ideas?!? It's driving me nuts! Thanks in advance... > -- > Dain Deutschman > CNA, MCP, CCNA > Data Communications Manager > New Star Sales and Service, Inc. Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=51555&t=51419 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]