Dear Quyen:
We use a couple of ZX GBIC between our two machine room
on the Cisco 3508, the distance is about 15-18 km,
and it works fine.
By the specification of ZX GBIC, the input power range
of ZX GBIC is -3dBm to -23 dBm,
so I think you will use the ZX GBIC well on your sites.
Best Regards
--
=====================================================
Kae Hsu [EMAIL PROTECTED] Sun CNA
Digital United Inc. Communication Network Dep.
9F, No. 220, Gangchi Road, Taipei 114, Taiwan, R.O.C.
TEL: (02)27983411 FAX: (02)26585758
=====================================================
""Nguyen Quyen"" Have anyone installed the Cisco GBIC ZX (WS-G5487)?
> We have the 12km singlemode fiber optic link between 2 site and we use 02
> Cisco 2950G-24 with 02 GBIC ZX. The end-to-end link attenuation was 7dB.
> The question is: we must use the additional attenuator? If yes, what kind
of
> it we must choose?.
>
> Pls help me! Thank a lot!
>
> Quyen
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=51615&t=51345
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]