You need to use the "channel-group" command to create the serial interface,
it doesn't do this automatically.  Here is an example from one that I have
done:
controller T1 2/1
  framing esf
  clock source internal
  linecode b8zs
  cablelength short 133
  channel-group 0 timeslots 1-24 speed 64

In this case, the "channel-group" command creates a serial 2/1:0 interface
that can then be given an IP address and used accordingly.


 -----Original Message-----
From:   [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]

Sent:   Thursday, October 03, 2002 9:42 AM
To:     [EMAIL PROTECTED]
Subject:        VWIC 2MFT-T1 [7:54796]

Has any one configured a Data T1 on the following card (VWIC 2MFT-T1)?  This
is very different from what I've seen in the past...

I've been looking on CCO for data configuration, but haven't found anything.
They say it's possible.

Cheers,
mkj

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Michael Jablonski
ABN AMRO Asset Management Holdings, Inc.
161 North Clark St.
9th Flr
Chicago, IL  60601-2468
PH: 312.884.2996 
FAX: 312.278.5550
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=54805&t=54796
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to