You need to use the "channel-group" command to create the serial interface, it doesn't do this automatically. Here is an example from one that I have done: controller T1 2/1 framing esf clock source internal linecode b8zs cablelength short 133 channel-group 0 timeslots 1-24 speed 64
In this case, the "channel-group" command creates a serial 2/1:0 interface that can then be given an IP address and used accordingly. -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] Sent: Thursday, October 03, 2002 9:42 AM To: [EMAIL PROTECTED] Subject: VWIC 2MFT-T1 [7:54796] Has any one configured a Data T1 on the following card (VWIC 2MFT-T1)? This is very different from what I've seen in the past... I've been looking on CCO for data configuration, but haven't found anything. They say it's possible. Cheers, mkj ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Michael Jablonski ABN AMRO Asset Management Holdings, Inc. 161 North Clark St. 9th Flr Chicago, IL 60601-2468 PH: 312.884.2996 FAX: 312.278.5550 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=54805&t=54796 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]