Hi

  I kindly ask your help about Dual Leaky Bucket on 6000 switches and
  LS1010 ATM switch


  The following definition is from the Cisco page at
  http://cisco.com/warp/public/473/152.html#eigth


  "Data from the second bucket is sent at a rate defined by the erate
  parameter minus the rate parameter"


  In the example:
  Console> (enable) set qos policer aggregate AGG1 rate 10000 policed-dscp
  erate 12000 drop burst 13 eburst 13

  data in the second bucket is sent at 12000 minus 10000.


  For the LS1010 Dual Leaky I found that the data is transmitted at the
  value specified in the erate.




  Is the algorithm different for the 6000 family compared to the LS1010 ?

  Best Regards,

  Alaerte




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=57045&t=57045
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to