All,
        I'm having a problem that I don't understand and I was hoping
someone out there might be able to give me some insight. I have a 2503 with
an HDLC connection on Serial0 going out to my service provider. The
running-config is very basic (sanitized, of course):

version 11.2
!
ip subnet-zero
!
interface Serial0
 ip address x.x.x.18 255.255.255.252
 keepalive 9
 no fair-queue
!
interface Serial1
 shutdown
!
interface BRI0
 no ip address
 shutdown
!
router eigrp 100
 network 10.0.0.0
!
no ip classless
!
bridge 11 protocol ieee
end

The problem I am having is that the line protocol is bouncing, but neither
my provider nor I can find a problem. I have swapped all the cables AND the
router, but the problem persists. I noticed that the line protocol goes down
for 9 seconds, then is up for 18 seconds, then the cycle repeats. For S&G, I
lowered the keepalives to 2 seconds; sure enough, the line protocol dropped
for 2 seconds, then was up for 4. By removing keepalives altogether, the
circuit stays up! What is going on here? Am I missing something painfully
obvious?
Thanks!
Geoff Mossburg




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=62928&t=62928
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to