Hmmm,

The settings look fine (though sometime 1 stop bit can be tried as well). 
Also verify flow control is set to none.

The cisco rollover cable is 1-8 = 8-1 pinouts.  I'm guessing you are 
using the cisco adapters and cable?


www.ccie4u.com


On 22 Feb 2003 at 12:49, puro prasad wrote:

> Hi,
> Unable to login to 7200vxr series router through console. Port settings on
> the terminal: 9600 baud, 8 data bits, no parity, 2 stop bits. Tried using
> other settings too, didn't help. Help!!
> Regs.,
> Prasad




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=63559&t=63555
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]