Hi

When I uncomment the NotifyClamd option I get the following error.

freshclam daemon started (pid=23740)
ClamAV update process started at Thu Apr 22 09:04:05 2004
main.cvd is up to date (version: 22, sigs: 20229, f-level: 1, builder: tkojm)
daily.cvd updated (version: 277, sigs: 951, f-level: 1, builder: ccordes)
Database updated (21180 signatures) from database.clamav.net.
ERROR: Clamd was NOT notified: Can't connect to clamd through /var/spool/MIMEDefang/clamd.sock


ls -la /var/spool/MIMEDefang/clamd.sock gives

srwxrwxrwx 1 defang defang 0 Apr 22 09:04 /var/spool/MIMEDefang/clamd.sock

Any clues as to the problem?

Cheers
Bill

Trog wrote:

clamdscan sends the file to clamd to scan. You need to tell clamd to
reload the database when it is updated. See the NotifyClamd option in
the freshclam.conf and the SelfCheck option in clamav.conf

-trog



Reply via email to