Hello, All: clamav-0.101.2-win-x64-portable clamav-0.101.3-win-x64-portable
After clamd.exe runs successfully for several hours, it becomes unresponsive. Hosted on 2 Windows 2016 Servers and a Windows 10 - all respond the same. Last log entry for clamd shows: "SelfCheck: Database status OK." An example of the unresponsive timelines from one of the deployments is pasted below. Restarted Unresponsive: Timespan: 8/10/19 01:30:30 a.m. 8/10/19 06:06:29 a.m. 4:35:59 8/10/19 06:06:30 a.m. 8/10/19 12:34:12 p.m. 6:27:42 8/10/19 12:34:13 p.m. 8/10/19 07:01:55 p.m. 5:32:18 8/10/19 07:01:56 p.m. 8/11/19 01:29:37 a.m. 5:32:19 8/11/19 01:29:38 a.m. 8/11/19 06:05:35 a.m. 4:35:57 8/11/19 06:05:37 a.m. 8/11/19 12:33:17 p.m. 6:27:40 8/11/19 12:33:19 p.m. 8/11/19 07:01:00 p.m. 5:32:19 8/11/19 07:01:01 p.m. 8/12/19 01:28:42 a.m. 6:27:41 Clamd.exe remains responsive for the timespans listed above, but then becomes unresponsive and I have to kill the process and start a new instance of clamd.exe. (The outage time consistency is telling, but what it's telling I still don't know.) FWIW: I run freshclam once an hour, but it seems to have no impact on the unresponsiveness of clamd. Also, the clamd.exe becomes unresponsive whether or not there are files being scanned. I've tried a few .conf changes with no noticeable impact on the unresponsiveness. Any pointers/tools/suggestions are greatly appreciated. I've appended my current .conf results to this email. Thanks for your time & have a great day! -Dave, clamconf -n Checking configuration files in C:\MyStuff\Tools\ClamAv\clamav-0.101.3-win-x64-portable Config file: clamd.conf ----------------------- LogFile = "C:\MyStuff\Tools\ClamAv\clamav-0.101.3-win-x64-portable\clamd.log" LogFileMaxSize = "2097152" LogTime = "yes" LogVerbose = "yes" TCPSocket = "3310" TCPAddr = "127.0.0.1" SendBufTimeout = "200" IdleTimeout = "60" SelfCheck = "1200" Config file: freshclam.conf --------------------------- LogFileMaxSize = "2097152" LogTime = "yes" UpdateLogFile = "C:\MyStuff\Tools\ClamAv\clamav-0.101.3-win-x64-portable\freshclam.log" DatabaseMirror = "database.clamav.net" clamav-milter.conf not found Software settings ----------------- Version: 0.101.3 Optional features supported: MEMPOOL AUTOIT_EA06 BZIP2 LIBXML2 PCRE2 RAR JIT Database information -------------------- Database directory: C:\MyStuff\Tools\ClamAv\clamav-0.101.3-win-x64-portable\database bytecode.cvd: version 330, sigs: 94, built on Wed Jul 17 08:11:08 2019 daily.cld: version 25540, sigs: 1713558, built on Tue Aug 13 03:16:47 2019 main.cvd: version 58, sigs: 4566249, built on Wed Jun 7 16:38:10 2017 Total number of signatures: 6279901 Platform information -------------------- uname: Microsoft Windows 6.2 SP0.0 Build 9200 OS: win32, ARCH: x86_64, CPU: x86_64 zlib version: 1.2.11 (1.2.11), compile flags: 65 Triple: x86_64-pc-win32 CPU: i686, Little-endian platform id: 0x102566660800077c0100077c Build information ----------------- Microsoft Visual C++: (0.7.124) Microsoft Visual C++ 1916 sizeof(void*) = 8 Engine flevel: 102, dconf: 102 _______________________________________________ clamav-users mailing list [email protected] https://lists.clamav.net/mailman/listinfo/clamav-users Help us build a comprehensive ClamAV guide: https://github.com/vrtadmin/clamav-faq http://www.clamav.net/contact.html#ml