Hi Rob,
I try with my openSBC and the x-lite can register successfully. However, I meet
issue since the users registering via X-lite can not call each other. I find
the INVITE message is terminated at Bono instead of I-CSCF/myOpenSBC. Is there
any config on clearwater needed to be done for the external PCSCF or not?
Thanks,Tam Vo
On Wednesday, June 24, 2015 11:51 PM, Robert Day
<[email protected]> wrote:
#yiv0911530201 #yiv0911530201 -- _filtered #yiv0911530201
{font-family:Helvetica;panose-1:2 11 6 4 2 2 2 2 2 4;} _filtered #yiv0911530201
{panose-1:2 4 5 3 5 4 6 3 2 4;} _filtered #yiv0911530201
{font-family:Calibri;panose-1:2 15 5 2 2 2 4 3 2 4;}#yiv0911530201
#yiv0911530201 p.yiv0911530201MsoNormal, #yiv0911530201
li.yiv0911530201MsoNormal, #yiv0911530201 div.yiv0911530201MsoNormal
{margin:0cm;margin-bottom:.0001pt;font-size:12.0pt;}#yiv0911530201 a:link,
#yiv0911530201 span.yiv0911530201MsoHyperlink
{color:#0563C1;text-decoration:underline;}#yiv0911530201 a:visited,
#yiv0911530201 span.yiv0911530201MsoHyperlinkFollowed
{color:#954F72;text-decoration:underline;}#yiv0911530201
span.yiv0911530201EmailStyle17 {color:#1F497D;}#yiv0911530201
.yiv0911530201MsoChpDefault {font-size:10.0pt;} _filtered #yiv0911530201
{margin:72.0pt 72.0pt 72.0pt 72.0pt;}#yiv0911530201
div.yiv0911530201WordSection1 {}#yiv0911530201 Hi Tam Vo, We’ve never tested
against openSBC specifically, but we’ve got no reason to think it wouldn’t work
– Sprout and Homestead form an IMS-compliant I-CSCF and S-CSCF, which will work
with any compliant P-CSCF, not just Bono. (We have successfully tested against
some other P-CSCFs to confirm this, just not openSBC in particular.) Good
luck integrating openSBC – we’d be interested to hear how you get on! Best,
Rob -- Rob Day Software Engineer, Project Clearwater From:
[email protected]
[mailto:[email protected]]On Behalf Of atva angel
Sent: 24 June 2015 17:31
To: Clearwater Mail
Subject: [Clearwater] Using external P-CSCF to interwork with clearwater
IMSCore Hi community, I have clearwater IMSCore is running with Bono
works as PCSCF. Now I want to have my openSBC (support PCSCF function) to have
integration into clearwater IMSCore to replace Bono to work as PCSCF. I'm not
sure if there's any configuration/limit for this case. Could you please help to
check and share your advice? Call model: IMS client(X-lite,...)----my
openSBC(PCSCF)-----Sprout(S/ICSCF)----Application server. Thanks, Tam Vo
_______________________________________________
Clearwater mailing list
[email protected]
http://lists.projectclearwater.org/listinfo/clearwater