Hi Mahibul, Thank you for your question and the helpful screenshots you have provided.
I can see that the configuration in your Zoiper client is missing a few crucial settings. You can follow the guide here<https://clearwater.readthedocs.io/en/stable/Making_your_first_call.html> to see how you should configure your clients. To add these settings in Zoiper go to Settings > Preferences. You should then enter the Auth. username ([email protected]) and the domain (example.com). There should also be a check box that you can check for using an outbound proxy. With all this in place your Zoiper preferences window should look like: [cid:[email protected]] Please let me know if you are able to register a subscriber with these settings. Thanks, Andrew From: Clearwater [mailto:[email protected]] On Behalf Of Sohag Hasan Sent: Saturday, May 27, 2017 4:59 PM To: [email protected] Subject: [Project Clearwater] Failed to register an account at Zoiper & X-Lite Dear Concern, I am trying to explore some features of IMS. I am using All-In-One Images of clearwater project in Virtualbox. I am facing problems to register soft Phone using SIP protocol. I created an SIP user using Ellies ( localhost:8080 ). [Inline image 1] Zopier settings: [Inline image 2] But I cannot register. For X-Lite, if I give the same credentials I get SIP 408 Error Could you please guide me how I can register on IMS. -- Thanks & Best Regards Mahibul Hasan Dhaka, Bangladesh