Hi,

I am trying to install clearwater using manual installation 
procedure(http://clearwater.readthedocs.io/en/stable/Manual_Install.html) . But 
when I try to create a number from ellis, it is automatically restarting and 
giving "failed to restart server" error.


Here is the logs from ellis

08-07-2017 20:47:21.822 UTC INFO main.py:88: Ellis process starting up
08-07-2017 20:47:22.041 UTC INFO web.py:1447: 200 GET /ping (0.0.0.0) 0.45ms
08-07-2017 20:47:32.131 UTC INFO web.py:1447: 200 GET /ping (0.0.0.0) 0.26ms
08-07-2017 20:47:32.143 UTC INFO web.py:1447: 200 GET /ping (0.0.0.0) 0.23ms
08-07-2017 20:47:35.559 UTC DEBUG numbers.py:105: Number allocation API call 
(PSTN = false)
08-07-2017 20:47:35.568 UTC DEBUG numbers.py:100: non-PSTN
08-07-2017 20:47:35.572 UTC DEBUG numbers.py:122: Fetched 
be20628b-e9f9-4bdf-8e95-cba6d0be7921
08-07-2017 20:47:35.573 UTC DEBUG numbers.py:114: SIP URI 
sip:[email protected]
08-07-2017 20:47:35.632 UTC DEBUG numbers.py:144: Populating other servers...
08-07-2017 20:47:35.633 UTC DEBUG numbers.py:155: About to create private ID at 
Homestead
08-07-2017 20:47:35.634 UTC INFO homestead.py:272: Sending HTTP PUT request to 
http://hs.example.com:8889/private/6505550494%40example.com
08-07-2017 20:47:55.646 UTC DEBUG numbers.py:160: Created private ID at 
Homestead
08-07-2017 20:47:55.648 UTC INFO homestead.py:272: Sending HTTP GET request to 
http://hs.example.com:8889/private/6505550494%40example.com/associated_implicit_registration_sets
08-07-2017 20:48:12.690 UTC INFO main.py:88: Ellis process starting up
08-07-2017 20:48:12.904 UTC INFO web.py:1447: 200 GET /ping (0.0.0.0) 0.41ms
08-07-2017 20:48:22.949 UTC INFO web.py:1447: 200 GET /ping (0.0.0.0) 0.16ms
08-07-2017 20:48:22.951 UTC INFO web.py:1447: 200 GET /ping (0.0.0.0) 0.23ms


And syslog from homestead and homer
Jul  9 10:37:47 ubuntu issue-alarm: zmq_msg_recv: Invalid argument
Jul  9 10:37:47 ubuntu issue-alarm: zmq_msg_recv: Invalid argument
Jul  9 10:37:47 ubuntu issue-alarm: zmq_msg_recv: Invalid argument
Jul  9 10:37:57 ubuntu issue-alarm: zmq_msg_recv: Invalid argument
Jul  9 10:37:57 ubuntu issue-alarm: zmq_msg_recv: Invalid argument
Jul  9 10:37:57 ubuntu cluster-manager[1595]: dropped request: 'issue-alarm 
cluster-manager 8003.1'
Jul  9 10:37:59 ubuntu queue-manager[10303]: dropped request: 'issue-alarm 
queue-manager 9001.1'
Jul  9 10:38:00 ubuntu cluster-manager[1595]: dropped request: 'issue-alarm 
cluster-manager 8000.1'
Jul  9 10:38:01 ubuntu queue-manager[10303]: dropped request: 'issue-alarm 
queue-manager 9002.1'
Jul  9 10:38:01 ubuntu CRON[26641]: (root) CMD (/usr/lib/sysstat/sadc 1 1 
/var/log/sysstat/clearwater-sa`date +%d` > /dev/null 2>&1)
Jul  9 10:38:07 ubuntu issue-alarm: zmq_msg_recv: Invalid argument
Jul  9 10:38:07 ubuntu issue-alarm: zmq_msg_recv: Invalid argument
Jul  9 10:38:07 ubuntu issue-alarm: zmq_msg_recv: Invalid argument




I can see all other services in other nodes are running.

I have one question, I have tried allinone build instructions as mentioned in 
http://clearwater.readthedocs.io/en/stable/All_in_one_Images.html#manual-build. 
It worked for me. The packages we used in aio setup are like homer-node, 
homestead-node and so on. But in manual build instructions, we are using homer, 
homestead etc., Does this make difference, which one to use? Do we need to 
update the manual build instructions?

And aio setup we are not using vellum, can we safely skip vellum in manual 
multinode setup too? If yes, how we can achieve that?


Any help/suggestion would be much appreciated.



Regards

Bharath T





_______________________________________________
Clearwater mailing list
[email protected]
http://lists.projectclearwater.org/mailman/listinfo/clearwater_lists.projectclearwater.org

Reply via email to