Hi Timur,

You need to run your configuration through "click-align" to correct the 
Classifier error.

Eddie


Timur Alperovich wrote:
> Hi,
> 
> I am trying to use roofnet and click on the gumstix. I thought it cross
> compiled fine, but when I try to run gen_config_safe.pl I end up with the
> following message:
> <stdin>:18: While configuring 'from_dev :: FromDevice':
>   warning: not using PCAP capture method, BPF filter ignored
> <stdin>:27: While configuring 'wifi_cl :: Classifier':
>   no AlignmentInfo available: you may experience unaligned accesses
> Router could not be initialized!
> 
> What could this be related to? I compiled click for arm using the 
> 2.6.19kernel.
> 
> Thank you,
> Timur
> _______________________________________________
> click mailing list
> [email protected]
> https://amsterdam.lcs.mit.edu/mailman/listinfo/click
_______________________________________________
click mailing list
[email protected]
https://amsterdam.lcs.mit.edu/mailman/listinfo/click

Reply via email to