On 01/30/2012 10:58 AM, Marek 'marx' Grac wrote:
For fencing purposes we have to focus on getting OFF status
when machine is really 100% down, conditions for ON status are much simplier
(as fact that machine is has power does not mean that it works). This patch
specify condition for OFF status - in fact only 'Down' is accepted now

Resolves: rhbz#769681
---
  fence/agents/rhevm/fence_rhevm.py |    6 +++---
  1 files changed, 3 insertions(+), 3 deletions(-)

diff --git a/fence/agents/rhevm/fence_rhevm.py 
b/fence/agents/rhevm/fence_rhevm.py
index 65a7395..3578b5f 100644
--- a/fence/agents/rhevm/fence_rhevm.py
+++ b/fence/agents/rhevm/fence_rhevm.py
@@ -41,10 +41,10 @@ def get_power_status(conn, options):
        else:
                status = result.group(1)

-       if (status == "up"):
-               return "on"
-       else:
+       if (status.lower() == "down"):
                return "off"
+       else:
+               return "on"

  def set_power_status(conn, options):
        action = {


This looks correct based on the bugzilla.

-- Lon

Reply via email to