Perhaps a bit more detail might help diagnose the root cause. After the
initial screen display, for example, pressing PF8 to scroll down in this case:
>O> "PIPE xedit| take 40| qdi 80 43 7654312 2 ? XEDIT 1 3 |
fullscr | stem attnid."
PIPIOS292E I/O error on CONSOLE; CSW X'000015D0 0020FFFF', CCW X'2AD4AFF0 2080F
PIPMSG003I ... Issued from stage 4 of pipeline 1.
PIPMSG001I ... Running "fullscr".
+++ RC(292) +++
Mike Walter
Aon Corporation
The opinions expressed herein are mine alone, not necessarily those of my
employer.
-----Original Message-----
From: CMSTSO Pipelines Discussion List [mailto:[email protected]] On
Behalf Of Mike Walter
Sent: Friday, May 16, 2014 09:52
To: [email protected]
Subject: FULLSCR stage error PIPIOS292E
When running QDI against any file, after the initial screen display, pressing
any AID key causes message:
PIPIOS292E I/O error on CONSOLE; CSW X'000015D0 0020FFFF', CCW X'2AD31640
2080FF FF'.
PIPMSG003I ... Issued from stage 4 of pipeline 1.
PIPMSG001I ... Running "fullscr".
Due diligence:
piplevel
PIPINX560I CMS/TSO Pipelines, 5654-030/5655-A17 level 110C000A.
PIPINX086I CMS/TSO Pipelines, 5654-030/5655-A17 1.0112 (Version.Release/Mod) -
Generated 24 Jul 2012 at 06:07:28
Source: Princeton Runtime Distribution
Msg 292E is documented as only being displayed for locally attached terminals,
not for terminals connected not PVM, VM/VCNA, or VM/VTAM.
This terminal runs from a Windows 7 laptop, running Bluezone terminal emulator,
connected via TN3270/TN3270E using TN3270SSL from a z/OS system's VTAM USS
display (i.e. VTAM encapsulation within TCP/IP, if I have the terms right).
When coming in purely via Telnet, FULLSCR causes no errors.
I 'noted' the "System Programmer Response" to the msg, but it offers no
solution, nor any "User Response".
Thoughts/diagnostic tips?
Mike Walter
Aon Corporation
The opinions expressed herein are mine alone, not necessarily those of my
employer.