On 3/18/2015 12:27 PM, Rob van der Heij wrote:
> On 18 March 2015 at 17:11, Glenn Knickerbocker <[email protected]> wrote:
>> But why don't FLOOR and CEILING coexist with AUTOADD?
> The floor/ceiling cause it to match, so there is no unmatched to add.

AUTOADD adds the record to the reference regardless of matches, and the
default is to add it AFTER processing on the primary, so it doesn't
match itself.  That's equivalent to what I wound up with, using FANOUT
to feed input 2:

  (end /) ... | a: fanout | b: lookup ceiling ... / b: | ... / a: | b:

¬R