OK, I will do as you adviced. Drawback: such a REXX fails when
called from CMS command line.

(The free WiFi Cafe is closing at 1800, so TNX and nice WE!)

Ciao.....Mike

Am 14.05.2016 um 17:47 schrieb Kris Buelens:
> The problem is that the added PIPE runs independently of the REXX stage
> that added it.  That REXX stage may have ended long before the added pipe
> ends (or even before it really starts).  That's the reason why VAR and
> Friend in an added PIPE don't even try to set variables in the REXX that
> added it, but a level lower.
>
> To pass "things" to the REXX that added the pipe section, other techniques
> must be used, like an extra input stream.  A simple solution for this case:
> use a CALLPIPE to grab the variable that was set a level lower:
>  'PEEKTO record'
>  if rc=0 then 'CALLPIPE VAR Where 1!Var Where'

--
www.Ok.de - die kostenlose E-Mail Adresse