Michael, You're doing string compares, so "-0......" is less than "-1". You'll also find that "-2000000.0000000" will not pass your filter... Try ... | pick substr 1 of w2 = /-/ and substr 2-* of w2 >>= /00000001.000000/ | ...
Op dinsdag 23 augustus 2016 heeft Michael Marrer <[email protected]> het volgende geschreven: > This would seem to be basically working, as I do get the numbers less > than negative 1 in the output file: > > pipe ' (end ?) < ' filename filetype filemode, > '| pick w2 <= /-1/ ', > '| > ' filename ' WORDOVER ' filemode, > ' ' > > The problem is that I get ALL negative numbers, not just those less > than negative 1. For example, these get selected as well: > > - > > -00000000.007800 > > So does anyone have any idea what is going wrong? > > I know I can also accomplish what I want by defining the word with a > variable in a SPECs stage and doing an IF/THEN operation, but as I > will be doing other tests on that word as well as other words in the > data file, it will get a little convoluted. > > I believe this represents the level of Pipes we are using: > > 11 Rev 0C Mod 0002 > 110C0002 > -- Ronald van der Laan