Decided to give Mike's pipe a try, but it gives me an error:

pipe literal *|dup 8|spec if #0=='' then set #0:=-5 else set #0+=1 endif print 
#0 n|Cons

"
FPLSPX1086E Improper operand for string comparison                         
FPLMSG003I ... Issued from stage 3 of pipeline 1                           
FPLMSG001I ... Running "spec if #0=='' then set #0:=-5 else set #0+=1 endi"
FPLSPE192I ... Scan at position 9; previous data "if #0==''"               
Ready (01086); T=0.01/0.01 12:06:48                         
"

Any ideas?


--Shawn S.


-----Original Message-----
From: CMSTSO Pipelines Discussion List [mailto:CMS-PIPELINES@VM.MARIST.EDU] On 
Behalf Of Michael Harding
Sent: Tuesday, June 28, 2016 15:32
To: CMS-PIPELINES@VM.MARIST.EDU
Subject: Re: [CMS-PIPELINES] Speaking of SPECS NUMBER

pipe literal *|dup 8|spec if #0=='' then set #0:=-5 else set #0+=1 endif print 
#0 n|Cons
         -5
         -4
         -3
         -2
         -1
          0
          1
          2
          3
Ready; T=0.01/0.01 13:26:02

--
Mike Harding
z/VM System Support

> From: "John P. Hartmann" <jphartm...@gmail.com>
> To: CMS-PIPELINES@VM.MARIST.EDU
> Date: 06/28/2016 01:01 PM
> Subject: Re: Speaking of SPECS NUMBER
> Sent by: CMSTSO Pipelines Discussion List 
> <CMS-PIPELINES@VM.MARIST.EDU>
>
> #0 will never become positive.  Is that what you wanted?

Reply via email to